![]() Visible Eye™ is a fully integrated Eye Tracking and Visual Stimulation system for fMRI/MEG applications. Visible Eye™ combines the Real Eye RE-4501 eye imaging system and the SV-7021 Fiber Optic Visual System supplied by Avotec, Inc. with the XView eye tracking system supplied by SensorMotoric Instruments, GmbH. Visible Eye™ Applications:
Eye Tracking information:
The Visible Eye™ system consists of three subsystems: The Avotec Silent VisionTM SV-7021 Fiber Optic Visual System allows patients to watch video material or computer generated images simply by using a pair of lightweight fiber optic glasses. A color LCD projector, located just outside the MRI bore, generates high resolution color images that are transmitted to the glasses by fiber optic image guides. A video interface, located in the control room, accepts video and computer inputs, and sends them to the projector via a fiber optic link. It also provides control monitors for the operator. The new Avotec
Real EyeTM fiber optic subsystem which is integrated with the
Silent VisionTM glasses, relays real time images of the patient eye
out of the magnet environment. Near infrared eye illumination
ensures optimum eye image quality without interfering with visual
stimulation. A low profile design ensures minimal interference
with the typically cramped space around the patient's head.
All parts of the system placed inside the magnet are composed
entirely of glass and plastic, so the system is truly inert even in
particularly high magnetic fields. The iViewTM eye tracking system analyzes the eye
images provided by RealEyeTM. The iView sampling rate is 50 Hz. Either the left or right
eye can be tracked. An automatic calibration procedure is
integrated into the system. The operator unit, located in the
control room, allows live monitoring of gaze position overlaid on
stimulus images, as well as digital recording and digital or analog
on-line output of eye movement data. SMI iView-fMRI EyeTM Tracking System Performance Specifications, System Version 0.91 (when used as part of Visible Eye System, for example in combination with Avotec Real EyeTM eye imaging unit and Avotec Silent VisionTM stimulus display for fMRI): Temporal Resolution: Sampling rate 60 Hz (NTSC version, US and Japan) / 50 Hz (PAL version, Europe) Tracking Range: 15-20 degrees horizontally, 10-15 degrees vertically (subject dependent) Gaze Position Accuracy: 3 degrees visual angle (2 minutes after calibration)
|
|